Input
Use S6:19 Figure 5.3 for reference. Valid table range: 1.0 to 3.0 m.
Terminal rows marked ≥ use the listed value for longer lengths.
Live update enabled
S6:19 reference table and interpolation basis
| Sp, m | Unstiffened edge | Edge stiffened with New Jersey barrier | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Maximum My, kN·m/m | Maximum My, kN·m/m | |||||||||
| L, m | rt=1.0 | 0.833 | 0.667 | 0.5 | L, m | rt=1.0 | 0.833 | 0.667 | 0.5 | |
Interpolation sequence: rt within each row, L within each edge-condition table, then Sp between adjacent groups. The Sp=1.0 row applies to all L. Values below the first listed L use the first row; values beyond a terminal ≥ row use that terminal row.